Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Pesqui. vet. bras ; 38(9): 1834-1837, set. 2018. tab
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-976516

RESUMO

The objective of this research was to determine in necropsied dogs the best time for fixation in ethylic alcohol (EA) and preservation in 30% sodium chloride aqueous solution (SCAS 30%), aiming micro-surgical training. Five groups of necropsied dogs (G1 to G5) were fixed with EA, and put in boxes containing EA for 30 (G2), 60 (G3), 90 (G4) or 120 days (G5). After that, each group was preserved in SCAS 30% for 120 days. The control group (G1) was composed by cadavers without fixation/preservation. At the end of each period, two fragments of external jugular vein per cadaver were collected, for traction test. Immediately after the collection, the cadavers femoral veins were evaluated (by 2 people) regarding the suture quality in binocular surgical microscope, and attributed scores from 0 (bad) to 5 (excellent), regarding the fresh samples. The average at the maximum rupture strength of the G3 fixation end (21.51N), such as the average of the G2 preserving end (21.62N) remained closer to the control group (19.98N) and the G2 was the group with the best score for venous suture training. The EA was efficient as a fixative just like SCAS as a dog cadavers' preservative. The small change of the traction test values, together with the best suture score, indicated the group kept for 30 days in EA and SCAS (G2) as the best for venous micro-surgical training.(AU)


O objetivo deste trabalho foi determinar, em cadáveres de cães, o melhor tempo para fixação em álcool etílico (AE) e conservação em solução aquosa de cloreto de sódio (SACS) a 30% visando o treinamento microcirúrgico. Cadáveres de cinco grupos (G1 a G5) foram fixados com AE e colocados em caixas contendo AE por 30 (G2), 60 (G3), 90 (G4) ou 120 days (G5). Depois, cada grupo foi conservado em SACS 30% por 120 dias. O grupo controle (G1) foi composto de cães sem fixação/conservação. Ao final de cada período, 2 fragmentos da veia jugular externa por cadáver foram coletados para o teste de tração. Imediatamente após a coleta, as veias femorais foram avaliadas (por 2 pessoas) em relação à qualidade da sutura em microscópio cirúrgico binocular, e atribuídos escores de 0 (péssimo) à 5 (excelente), em relação às amostras frescas. A média da força máxima de ruptura no G3 no final da fixação (21,51N), assim como a média do G2 no final da conservação (21,62N) foram as que mais se mantiveram próxima do grupo controle (19,98N) e o G2 foi o grupo com o melhor escore para treinamento da sutura venosa. O AE foi eficiente como fixador assim como a SACS foi efetiva na conservação de cadáveres de cães. A pequena alteração nos valores do teste de tração, junto com o melhor escore para sutura, indicaram o grupo mantido por 30 dias em AE e SACS (G2) como o melhor para treinamento venoso microcirúrgico.(AU)


Assuntos
Animais , Cães , Técnicas de Sutura/veterinária , Etanol/análise , Cães/cirurgia , Solução Salina Hipertônica
2.
São José dos Campos; s.n; 2014. 142 p. ilus, tab, graf.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-867618

RESUMO

O objetivo deste estudo foi empregar diferentes abordagens estatísticas emdados obtidos em ensaios de micro e macrotração, em dois períodos detempo de armazenamento, a fim de descrever e quantificar a variabilidadecomumente encontrada nos testes de adesão. Foram selecionados 48 dentes bovinos. As raízes seccionadas a 2 mm abaixo da junção cementoesmaltee as faces vestibulares foram desgastadas expondo superfície dedentina plana. Os dentes foram embutidos em resina acrílica ealeatoriamente designados a quatro grupos (n = 12) para avaliação daresistência de união (RU). Para o teste de microtração foi aplicado o adesivoAdper Single Bond 2- (SE Bond 2- 3M-ESPE) numa área de 8 mm2, seguidode jato de ar por 2 a 5 s e fotopolimerização por 15 s e, a seguir, inserida a resina composta Z350 XT- (3 M-ESPE). Após 24 h de armazenamento, em água destilada a 37 ºC, para cada dente um número variável de palitos foiobtido. Doze dentes foram submetidos ao teste de microtração após 24 h (G1) e outros 12 submetidos à termociclagem (G2) seguido de microtração. Para a macrotração, a base menor dos espécimes cônicos foi de 2 mm. Doze amostras após 24 h foram submetidas ao teste de macrotração (G3) e as outras doze, após as 24 h, termocicladas (G4). Os dados foram submetidos a uma análise exploratória; seguidos de uma análise confirmatória (inferencial). A estatística descritiva e o resultado da análise de Weibull para os dados de RU (MPa) foram: G1(módulo; média ± desvio padrão: 2,54; 10,76 ± 4,21); G2 (3,36; 19,34 ± 6,42); G3 (1,96; 3,17 ± 1,51; G4 (1,75; 2,86 ± 1,68). O teste ANOVA (2-way), α = 5%, indica efeito interação significante e, os testes de Tukey e de Dunn (5%), complementaram os resultados. Pôde-se concluir: as diferentes estratégias estatísticas (análise de Weibull, análise exploratória e abordagem paramétrica) indicaram os mesmos resultados, ou seja, a existência do efeito envelhecimento, apenas, para a microtração; na comparação entre macro e microtração ...


The aim of this study was to use different statistical approaches on data obtainedfrom micro and macrotensile tests in two periods of time storage, in order todescribe and quantify the variability commonly found in adhesion tests. 48 bovine teeth were selected. The roots were sectioned 2 mm below the cement-enamel junction and the buccal surfaces were ground to exposure a dentin flat surface. The teeth were embedded in acrylic resin and randomly assigned to four groups (n = 12) to evaluate the bond strength (BS). For the microtensile test the adhesive Adper Single Bond 2 - (2 SE Bond - 3M - ESPE) was applied in an area of 8 mm2, followed by air jet during 2 to 5 s and curing for 15 s. Right after the XT - Z350 composite resin (3M ESPE) was inserted. After 24 h of storage in distilled water at 37 °C, for each tooth a variable number of sticks was obtained. Twelve teeth were submitted to microtensile test after 24 h (G1) and other 12 to thermocycling (G2) and microtensile test. For macrotensile, the smallest base of conical shape specimens was 2 mm. After 24 h twelve samples were subjected to macrontesile test (G3) and the other twelve, after 24 h, were thermocycled (G4). The data were submitted to an exploratory analysis, followed by a (inferential) confirmatory analysis. Descriptive statistics and the results of Weibullanalysis for the data of BS (MPa) of the experimental conditions were: G1(module; mean ± standard deviation: 2.54; 10.76 ± 4.21); G2 (3.36; 19.34 ± 6.42); G3 1.96; 3.17 ± 1.51; G4 (1.75; 2.86 ± 1.68). The ANOVA (2-way), α = 5%, indicated significant interaction effect, and Tukey tests and Dunn (5%),complemented the results. The conclusion is: the different statistics strategies (Weibull analysis, exploratory analysis and parametric approach) showed the same results, namely the existence of the aging effect only for the microtensile bond; in the comparison between macro and microtensile (model 2-way ANOVA), direct evaluation between tests ...


Assuntos
Bioestatística , Distribuições Estatísticas , Teste de Materiais
3.
São José dos Campos; s.n; 2014. 142 p. ilus, tab, graf.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-870207

RESUMO

O objetivo deste estudo foi empregar diferentes abordagens estatísticas emdados obtidos em ensaios de micro e macrotração, em dois períodos detempo de armazenamento, a fim de descrever e quantificar a variabilidadecomumente encontrada nos testes de adesão. Foram selecionados 48 dentes bovinos. As raízes seccionadas a 2 mm abaixo da junção cementoesmaltee as faces vestibulares foram desgastadas expondo superfície dedentina plana. Os dentes foram embutidos em resina acrílica ealeatoriamente designados a quatro grupos (n = 12) para avaliação daresistência de união (RU). Para o teste de microtração foi aplicado o adesivoAdper Single Bond 2- (SE Bond 2- 3M-ESPE) numa área de 8 mm2, seguidode jato de ar por 2 a 5 s e fotopolimerização por 15 s e, a seguir, inserida a resina composta Z350 XT- (3 M-ESPE). Após 24 h de armazenamento, em água destilada a 37 ºC, para cada dente um número variável de palitos foiobtido. Doze dentes foram submetidos ao teste de microtração após 24 h (G1) e outros 12 submetidos à termociclagem (G2) seguido de microtração. Para a macrotração, a base menor dos espécimes cônicos foi de 2 mm. Doze amostras após 24 h foram submetidas ao teste de macrotração (G3) e as outras doze, após as 24 h, termocicladas (G4). Os dados foram submetidos a uma análise exploratória; seguidos de uma análise confirmatória (inferencial). A estatística descritiva e o resultado da análise de Weibull para os dados de RU (MPa) foram: G1(módulo; média ± desvio padrão: 2,54; 10,76 ± 4,21); G2 (3,36; 19,34 ± 6,42); G3 (1,96; 3,17 ± 1,51; G4 (1,75; 2,86 ± 1,68). O teste ANOVA (2-way), α = 5%, indica efeito interação significante e, os testes de Tukey e de Dunn (5%), complementaram os resultados. Pôde-se concluir: as diferentes estratégias estatísticas (análise de Weibull, análise exploratória e abordagem paramétrica) indicaram os mesmos resultados, ou seja, a existência do efeito envelhecimento, apenas, para a microtração; na comparação entre macro e microtração...


The aim of this study was to use different statistical approaches on data obtainedfrom micro and macrotensile tests in two periods of time storage, in order todescribe and quantify the variability commonly found in adhesion tests. 48 bovine teeth were selected. The roots were sectioned 2 mm below the cement-enamel junction and the buccal surfaces were ground to exposure a dentin flat surface. The teeth were embedded in acrylic resin and randomly assigned to four groups (n = 12) to evaluate the bond strength (BS). For the microtensile test the adhesive Adper Single Bond 2 - (2 SE Bond - 3M - ESPE) was applied in an area of 8 mm2, followed by air jet during 2 to 5 s and curing for 15 s. Right after the XT - Z350 composite resin (3M ESPE) was inserted. After 24 h of storage in distilled water at 37 °C, for each tooth a variable number of sticks was obtained. Twelve teeth were submitted to microtensile test after 24 h (G1) and other 12 to thermocycling (G2) and microtensile test. For macrotensile, the smallest base of conical shape specimens was 2 mm. After 24 h twelve samples were subjected to macrontesile test (G3) and the other twelve, after 24 h, were thermocycled (G4). The data were submitted to an exploratory analysis, followed by a (inferential) confirmatory analysis. Descriptive statistics and the results of Weibullanalysis for the data of BS (MPa) of the experimental conditions were: G1(module; mean ± standard deviation: 2.54; 10.76 ± 4.21); G2 (3.36; 19.34 ± 6.42); G3 1.96; 3.17 ± 1.51; G4 (1.75; 2.86 ± 1.68). The ANOVA (2-way), α = 5%, indicated significant interaction effect, and Tukey tests and Dunn (5%),complemented the results. The conclusion is: the different statistics strategies (Weibull analysis, exploratory analysis and parametric approach) showed the same results, namely the existence of the aging effect only for the microtensile bond; in the comparison between macro and microtensile (model 2-way ANOVA), direct evaluation between tests...


Assuntos
Bioestatística , Distribuições Estatísticas , Teste de Materiais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...